Solution to the problem of small rotary tablet press failure

The small rotary tablet press is not paying attention to maintenance during use, or due to the operator's improper operation leading to some minor faults, the solution is summarized as follows:
Fault 1: The difference in sheet weight exceeds the standard solution: the feeder is worn or not installed correctly. Please change the wearer of the feeder. If it is not properly installed, adjust it in time. For die problems, check the total length of the upper and lower punches. If it is out of tolerance, stop using it.
Fault 2: The upper and lower pressure wheel shafts are tilted. Solution: The pressure roller shaft is oil-destroyed, the wear is slight, and the oil is repaired after repair. Serious wear and tear, replace immediately.
Fault 3: The method of track wear on the tablet press: It is the dry grinding of the oil, which causes the track surface to be slightly damaged. It should be repaired in time, and the damage should be replaced.