Human pancreatic amylase (PAMY) kit instruction manual
Human pancreatic amylase (PAMY) kit technical data
- This kit is for research use only.
- ELISA kit price: welcome to call us
Storage conditions and expiration date:
1. Kit storage: 2-8 ° C.
2. Validity: 6 months
Detection range: 48T 25 ng/L -800 ng/L
purpose of usage:
This kit is used to determine the content of pancreatic amylase (PAMY) in human serum, plasma and related liquid samples.
Experimental principle
The kit uses a double antibody sandwich assay to determine the level of human pancreatic amylase (PAMY) in the specimen. The microplate was coated with purified human pancreatic amylase (PAMY) antibody to prepare a solid phase antibody, and the pancreatic amylase (PAMY) was sequentially added to the microcapsule of the coated monoclonal antibody, followed by HRP-labeled pancreatic amylase. The class (PAMY) antibody binds to form an antibody-antigen-enzyme-labeled antibody complex, which is thoroughly washed and then added to the substrate TMB for color development. TMB is converted to blue under the catalysis of HRP enzyme and converted to the final yellow color by the action of an acid. The color depth is positively correlated with the pancreatic amylase (PAMY) in the sample. The absorbance (OD value) was measured with a microplate reader at a wavelength of 450 nm, and the concentration of human pancreatic amylase (PAMY) in the sample was calculated from a standard curve.
Kit composition
1 | 20 times concentrated washing solution | 20ml × 1 bottle | 7 | Stop solution | 3ml × 1 bottle |
2 | Enzyme standard reagent | 3ml × 1 bottle | 8 | Standard product (1600ng/L) | 0.5ml × 1 bottle |
3 | Enzyme label coated plate | 12 holes × 4 | 9 | Standard dilution | 1.5ml × 1 bottle |
4 | Sample diluent | 3ml × 1 bottle | 10 | Instruction manual | 1 copy |
5 | Developer A solution | 3ml × 1 bottle | 11 | Sealing film | 2 sheets |
6 | Developer B solution | 3ml×1/bottle | 12 | sealed bag | 1 |
Specimen requirements
1. The specimens should be extracted as soon as possible after collection, and the extraction should be carried out according to the relevant literature. The experiment should be carried out as soon as possible after extraction. If the test cannot be performed immediately, the specimen can be stored at -20 °C, but repeated freezing and thawing should be avoided.
2. Samples containing NaN3 could not be detected because NaN3 inhibited horseradish peroxidase (HRP) activity.
Steps
1. Dilution of standard: This kit provides one original standard, which can be diluted in a small tube according to the following chart.
800 ng/L | Standard No. 5 | Add 150 μl of standard dilution to 150 μl of the original standard |
400 ng/L | Standard No. 4 | Add 150 μl of standard dilution to 150 μl of standard #5 |
200 ng/L l | Standard No. 3 | Add 150 μl of standard dilution to 150 μl of standard #4 |
100 ng/L | Standard 2 | Add 150 μl of standard dilution to 150 μl of Standard #3 |
50 ng/L | Standard No. 1 | 150 μl of Standard 2 is added to 150 μl of standard dilution |
2. Adding samples: set blank holes respectively (the blank control wells are not added with the sample and the enzyme standard reagent, the other steps are the same), the standard holes, and the sample holes to be tested. Accurately load 50 μl of the standard on the enzyme-labeled plate, add 40 μl of the sample dilution to the well to be tested, and then add 10 μl of the sample to be tested (the final dilution of the sample is 5 times). Add the sample to the bottom of the well of the microplate, try not to touch the wall of the well, and shake gently to mix.
3. Incubation: The plate was sealed with a sealing film and incubated at 37 ° C for 30 minutes.
4. Liquor: 20 times concentrated washing solution diluted with distilled water 20 times and used
5. Washing: Carefully remove the sealing film, discard the liquid, dry it, fill each well with the washing solution, let stand for 30 seconds, then discard it, repeat 5 times, and pat dry.
6. Add enzyme: Add 50 μl of enzyme labeling reagent to each well, except for blank wells.
7. Incubation: The operation is the same as 3.
8. Wash: Operate the same as 5.
9. Color development: add 50 μl of color developer A, and then add 50 μl of color developer B, gently shake and mix, and color for 15 minutes at 37 °C.
10. Termination: 50 μl of stop solution was added to each well to stop the reaction (the blue color turned yellow).
11. Measurement: The absorbance (OD value) of each well was measured in sequence with a blank air conditioner of zero and a wavelength of 450 nm. The measurement should be carried out within 15 minutes after the addition of the stop solution.
Precautions:
1. The kit should be taken out from the refrigerated environment and should be used at room temperature for 15-30 minutes before use. If the enzyme label is unsealed after opening, the slats should be stored in a sealed bag.
2. Concentrated washing liquid may crystallize out. When diluted, it can be heated and dissolved in a water bath. The washing will not affect the result.
3. The sampler should be used for each step, and the accuracy should be corrected frequently to avoid test errors. The loading time is controlled within 5 minutes. If the number of specimens is large, it is recommended to use a gun.
4. Please make a standard curve at the same time for each measurement and make a double hole. If the content of the substance to be tested in the specimen is too high (the OD value of the sample is larger than the OD value of the standard pore), please first dilute the sample dilution with a certain multiple (n times) and then measure it. When calculating, multiply the total dilution factor ( ×n×5).
5. The sealing film is intended for single use only to avoid cross-contamination.
6. Please keep the substrate away from light.
7. Strictly follow the instructions of the manual, the test results must be based on the microplate reader reading.
8. All samples, washings and various wastes should be treated as infectious materials.
9. The different batch components of this reagent must not be mixed.
10. In the case of an English manual, the English manual shall prevail.
Storage conditions and expiration date
1. The kit is stored at: 2-8 °C.
2. Validity: 6 months
For your ordering convenience, choose from these top items within popular categories:
Applicators / Swabs
Aprons - Disposable
Bags / Kits
Bags / Wraps / Tubing
Bandages Gauze
Band-Aides
Bedpans & Urinals
Bibs
Blades / Scalpels - Disp
Blankets
Blood Collection needles
Blood Collection Tubes
Blood Tubing Sets
Bowls & Basins
Burn Care
Camera Drapes
Capes
Caps / Head Wear
Casting
Charts - Diagnostic
Chemistry & access
Chemotherapy
CholesterolMeter/Strip/Control
Circuits
Cleanup Kits / Bags
Collars
Conforming
Controls & Calibrators
Cotton
Debridement & Supplies
Defibrillator access
Diagnostic Thermal Paper
Dialyzers
Disinfectants Detergent Bleach
Dispensing Containers
Dressings
Drinking Fountains & access
Drug/Alcohol Tests
Ear / Utility / Air
ECG / EKG / EEG Paper
ECG / EKG / EEG Supplies
Elastic / Tubulars
Electro / Cryosurgery Supplies
Electrode-Diagnostic-Procedure
Emergency Bag & access
Endo Trach & Supplies
Environmental Safety
Exam Room Supplies
Extrication Tools
Eye Protection / Eye Wear
Face Masks
Fecal Occult Blood Tests
Feeding Tubes
Field Guides / Books / Videos
Filaments - Sensory
Fistula Needles
Footcare Management
Footwear
Forceps/Hemostat/Clamp Disp
Garments
Glass & Plastic Ware
Glove Access Glove Dispenser
Glove Access Liners
Glove Access MISC
Gloves Latex LP & PF Exam-Str
Gloves Latex LP Exam-NS
Gloves Latex LP Exam-Sterile
Gloves Latex LP Surg-Sterile
Gloves Latex PF Exam-NS
Gloves Latex PF Surg Sterile
Gloves Nitrile LP Exam-NS
Gloves Nitrile PF Exam-NS
Gloves Nitrile PF Exam-Str
Gloves NonLtx LF&PF Surg-Str
Gloves Vinyl Synth LP Exam-NS
Gloves Vinyl Synth PF Exam-NS
Gloves Vinyl/Synt LP Exam-Str
Gloves Vinyl/Synt PF Exam-Str
Glucose Meter-Strips-Controls
Gowns
Gowns / Aprons
H Pylori
Hazmat Identification
Head & Foot Wear
Hearing Protection
Hematology and access
Holster
Holter Supplies
Huber Needles
Ice Machines
Influenza
Instrument Care
Insulin Needles / Syringes
Irrigating Solutions
IV / Injection Training
IV Access
IV Catheters
IV Procedure Trays
IV Solutions
Jars / Tins / Boxes
Knee Braces & Supports
Lab Coats / Jackets / Smocks
Lab Supplies
Lancets
Linens - Disposable
Linens - Reusable
Manikins
Medical Publications
Medicated
Microbiology Testing & access
Microscope slides / Pipettes
Mono
Mouthguards
Mouthpieces
Nebulizers
Needles
Needles / Syringes
Orthotics / Shoe Inserts
Ostomy-Illeostomy-Supplies
Oxygen
Packs & Kits PU
Padding-Foam /Gel /Cast /Felt
Paste Bandages
Personal Care
Pillows / Cushion & Positioner
Pipettors / Pipettes & access
Post-Op Care
Pouches
Pregnancy
Probe Cover/Sheath - All Kinds
Protective Clothing
Racks
Radios & Communication
Reagents
Restraints
Resuscitation
Reusable Needles / Syringes
RSV
Scrubs
Self-Adherents
Sensi-disc
Sharps Bracket / Cabinet
Sharps Disposal
Shoe and Boot
Shoe Covers
Simulation Kits
Skin Punches - Disp
Soap - Hand Sanitizers
Sponges
Straps
Surg Supplies
Surgical Mesh
Suture Needles
Sutures / Supplies / Kits
Syringes
Test Tubes & access
Therapy Supplies
Thrombosis / Compression
Tongue Depressors
Tourniquets
Towels
Tray Covers
Trays...
Medical Items,Medical Disposables,Clinical Products
NOUVASANT GROUP LTD. , https://www.nouvasant.com