Monitoring and Analysis of Overheating of High Pressure Gear Pump Motor

The specific analysis and detection of the high-pressure gear pump motor overheating are as follows:

   1. The high-pressure gear pump has poor assembly quality. Is there a friction or a difference between the motor and the pump shaft?

Check assembly quality and troubleshoot assembly?

   2 , the packing gland pressure is too tight or the mechanical seal spring is too tight?

Re-adjust the amount of spring compression of the gland or mechanical seal

   3. Does the specific gravity of the medium exceed the high-pressure gear pump configuration motor?

Configure the appropriate high-pressure gear pump motor

   4 , the scope of use (flow, lift) exceeds the design requirements of the gear pump?

Select the right motor according to the series

According to the above conditions, we can analyze one by one to find out the real cause of overheating of the high-pressure gear pump motor, and repair it according to the corresponding fault.