Small shredder operation and precautions

Small Chinese medicine grinder operation process:

  1. Preparation: It should be noted that the material must be dry. If the material is not dry, it can be dried or dried (the small dryer that matches the factory has GZ9011 electric constant temperature drying oven), and the sugar powder is more More materials with higher fiber are not smashed. Then prepare the necessary items such as the receiving tray.
  2. Feeding: Open the top cover (counterclockwise, turn clockwise) and put the dry medicine into the crushing box. Close the cover and tighten the swing to fix the knob.
  3. Crush: Plug in the power and turn on the timer switch. Generally, Chinese medicine powder can be used for half a minute, and hard powder can be used for about 1 minute. It is not suitable for too long.
  4. Discharge: When the rolling sound is relatively uniform, it means that the medicine has been pulverized into powder, and it can be turned off. Loosen the swing fixing knob, open the top cover, and pour out the powder.

Small Chinese medicine crusher notes:

1. Applicable to the ambient temperature of -5oC - 40oC, relative humidity ≤ 90%, the temperature is suitable, should be placed in a ventilated, dry, clean position.
2. It is strictly forbidden for underage children to contact the machine without authorization to avoid accidents.
3. Before using the machine, it is necessary to determine whether the power supply voltage is normal and the power socket has a reliable grounding wire.
4. The dried material is pulverized finer. It is not advisable to process wet and greased items.
5. When the machine is working, the drug should not exceed half of the internal volume of the crusher.
6, the general Chinese medicine smash only takes 1 minute, the special need time is longer.
7, the machine can not work continuously for a long time, do not exceed 5 minutes each time, when the number of processing is large, the middle must rest, to prevent motor damage caused by overheating of the motor bearings.
8. When the machine is turned on, if it encounters the crushed object and the blade is stuck, the motor can not operate normally. It is necessary to turn off the power immediately to prevent the motor from being damaged and to work again after cleaning.
9. After long-term use, the carbon brushes and blades are severely worn and must be replaced.
10. Before each work, check whether the screws of the blade are loose to ensure safety.
11. Prevent the machine from falling to the ground and damage the machine. A relatively stable workbench should be placed.
12. If you find that the motor is not working properly, check the wiring or check the fuse.

Computed Tomography

A CT scan makes use of computer-processed combinations of many X-ray images taken from different angles to produce cross-sectional (tomographic) images (virtual "slices") of specific areas of a scanned object, allowing the user to see inside the object without cutting.

Digital Radiography made affordable, Created to meet the needs of community to hospitals and private radiology practices, it enables the price-sensitive customers to join the drive to go digital.The versatile floor mounted radiography system enables you to go from film to CR to DR.Flooe-mounted easy for installation and operation
The United-imaging is floor mounted system comprises a radiographic table with integral floor guide rail and a wallstabd. Requiring little room preparation, it is easy to install.
United-imaging according to the international advanced processing mode and standardlize design. the parts are made with precision CNC machine and moulding. Which adopt high degree of standardized, reasonable and compact structure. With reliable, durable and elegant appearance and advanced processing technology.


CT scannercomputed tomographydigital imaging machine Umi780 P1 Png



Computed Tomography,Medical Computed Tomography Scanning Machine,Medical Ct Scanner,Computed Tomography In Ct Scanner

Shanghai Rocatti Biotechnology Co.,Ltd , https://www.shljdmedical.com